329915

Graco G3TM Max Grease Pump, 90 240 VAC, 16L, Low Level with Controller, 3 Sensors, DIN, Machine Count, Vent Valve, Alarm, Remote Manual Run

From
$136.54
Learn More
Check Store Availability

We don't have enough stock on hand.

Adding to cart… The item has been added
Added to Cart

Features

Extend machinery life, reduce operating costs and increase productivity with a Graco G3 today! The G3 Max has a flexible design that works with injector-based and series progressive systems. A cost-effective pump designed to serve multiple markets and applications. Includes one adjustable pump element - standard, plus room for two more. The ultimate in flexibility - for a high value, custom fit on your application.

  • Built-in controller with selectable pump on/pump off timer
  • Low level indicator provides low warning and shut-down alarm
  • Manual run initiates lube cycle on-demand (remote option also available)
  • Password protection safeguards settings
  • Pre-lube function can initiate lube cycle on start-up
  • Up to three pressure or cycle switch inputs to ensure proper lubrication cycles
  • Mix/match cycle and pressure switches for custom installations and feedback
  • Machine count input - ideally suited for inconsistently used equipment
  • Fault indication to external alarms
  • Optional Data Management System (DMS)

    • Work faster and smarter with Graco's exclusive Data Management System (DMS)
    • Find out exactly how your lubrication system is performing and how well it's lubricated
    • Tracks history, provides data protection, upload or download data using a simple USB flash drive.

Specifications

UPC Product: 00633955595071
Family Code: FAMMPM
Unit of Measure: EA
Height: 28.8 IN | 73.152 CM
Length: 12 IN | 30.48 CM
Width: 12 IN | 30.48 CM
Volume: 2.4 FT3 | .068 M3
Chargeable Weight: 24.984 LBS | 11.327 KG

Technical Specifications

Type Electric Piston Pump
Application On-Road Vehicles, Off-Road Equipment
Compatible Material Grease
Fluid Outlet Size (in) 0.25
Fluid Outlet Size (mm) 6.3500
Fluid Outlet Thread Gender Female
Fluid Outlet Thread Type NPSF
For Use With ????????, ??????????????, Injector-Based Systems, Sistemas basados en inyectores, ????????, ???????????, Series Progressive Systems, sistemas progresivos en serie
Includes ????, ???????, Machine Count, Recuento de m?quina, ???, ??????, Vent Valve, v?lvula de ventilaci?n, DIN ????, DIN ??????, DIN Alarm Output, salida de alarma DIN, ???????? M12 ??, ????? M12 ??, M12 Connection for Remote, conexi?n M12 para control remoto, ??, ???????, Wiper Arm, brazo rascador, ???, ????, Low Level, nivel bajo
Maximum NLGI Grade #2
Maximum Working Pressure (bar) 351.6
Maximum Working Pressure (kPa) 35160
Maximum Working Pressure (psi) 5100
Model G3
Power Type Electric
Reservoir Size (gal) 4.23
Reservoir Size (L) 16
Series Max
Voltage (V ac) 90-240
Weight (lb) 13.3
Alarm Relay Inductive Maximum Operating Current (A) 1.5
Alarm Relay Inductive Maximum Operating Voltage (VAC) 250
Alarm Relay Inductive Maximum Switching Capacity 25 VA;30 W
Alarm Relay Inductive Rated Load (A) 0.2
Alarm Relay Resistive Maximum Operating Current (A) 3
Alarm Relay Resistive Maximum Operating Voltage (VAC) 250
Alarm Relay Resistive Maximum Switching Capacity 50 VA;60 W
Alarm Relay Resistive Minimum Permissible Load 10 ?A;10m VDC
Alarm Relay Resistive Rated Load (A) 0.4
Compatible Metering Device Series Progressive, Single Line Parallel
Control Options Max
Input Cycle Rate (Hz) 8
Input Impedance 1.1
Input Load Current (mA @ 24 VDC) 22
Input Maximum Off Current (mA) 1.5
Input Maximum Residual Voltage (V) 4
Input Required Switch Type Normally Open
Input Response Time (ms) 60
Input Sensor Voltage (VDC) 24
IP Rating IP69K
Low Level Carry Current (A) 1.2
Low Level Switching Current (A) 0.5
Maximum Fill Inlet Pressure (bar) 344.7
Maximum Fill Inlet Pressure (kPa) 34470
Maximum Fill Inlet Pressure (psi) 5000
Maximum Run Time (min) 30
Maximum Voltage (V ac) 264
Minimum Voltage (V ac) 88
Number of Machine Count Sensor Inputs 1
Number of Pressure and Cycle Sensor Inputs 3
Number of Pump Elements Up to 3
Number of Sensor Inputs 3, 1
Overall Depth (cm) 25.4
Overall Depth (in) 10
Overall Depth (mm) 254
Overall Height (cm) 69.9
Overall Height (in) 27.5
Overall Height (mm) 699
Overall Width (cm) 23.5
Overall Width (in) 9.25
Overall Width (mm) 235
Power Connection Type DIN
Pump Output with 0 Spacers (cu in/min) 0.25
Pump Output with 1 Spacer (cu in/min) 0.18
Pump Output with 2 Spacers (cu in/min) 0.12
Vent Valve Maximum Operating Current (A) 2
Vent Valve Maximum Operating Power (W) 48
Vent Valve Output Voltage (VDC) 24
Voltage (V) 90-240 VAC
Weight (kg) 6
Maximum Working Pressure (MPa) 35.1

WASHING INSTRUCTIONS:

Machine wash separately in cold water on a gentle cycle. Tumble dry separately on low heat. Add QE Home Wool Dryer Balls to reduce wrinkles and increases drying efficiency. Touch up with a low heat iron as needed. Do not bleach or dry clean.

Reviews